Simultaneous determination of dissolved organic nitrogen, nitrite, nitrate and ammonia using size exclusion
Wen-Xiang Ji1, Ye-Chao Tian1, Min-Hui Cai1
1State Key Laboratory of Pollution Control and Resources Reuse, School of the Environment, Nanjing University, Nanjing 210023, China.
Abstract:
Accurate quantification of dissolved organic nitrogen (DON) has been a challenge due to the cumulative analytical errors in the conventional method via subtracting dissolved inorganic nitrogen species (DIN) from total dissolved nitrogen (TDN). Size exclusion chromatography coupled with an organic nitrogen detector (SEC-OND) has been developed as a direct method for quantification and characterization of DON. However, the applications of SEC-OND method still subject to poor separations between DON and DIN species and unsatisfied N recoveries of macromolecules. In this study, we packed a series of SEC columns with different lengths and resin materials for separation of different N species and designed an independent vacuum ultraviolet (VUV) oxidation device for complete oxidation converting N species to nitrate. To guarantee sufficient N recoveries, the operation conditions were optimized as oxidation time ≥ 30 min, injection mass (sample concentration × injection volume) < 1000 µL × mg-N/L for macromolecular proteins, and neutral pH mobile eluent. The dissolved O2 concentration in SEC mobile phase determined the upper limit of VUV oxidation at a specific oxidation time. Compared to conventional HW50S column (20 × 250 mm), HW40S column (20 × 350 mm) with mobile phase comprising of 1.5 g/L Na2HPO4·2H2O + 2.5 g/L KH2PO4 (pH = 6.85) could achieve a better separation of DON, nitrite, nitrate, and ammonia. When applied to river water, lake water, wastewater effluent, groundwater, and landfill leachate, the SEC-OND method could quantify DON as well as DIN species accurately and conveniently even the DIN/TDN ratio reached 0.98.
Related Concept Videos
Gas Chromatography: Types of Detectors-II
High-Performance Liquid Chromatography: Types of Detectors
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...