Related Experiment Video
Updated: Aug 21, 2025

E-Patient Counseling Trial E-PACO: Computer Based Education versus Nurse Counseling for Patients to Prepare for Colonoscopy
Published on: August 1, 2019
Predicting Inadequate Bowel Preparation When Using Sodium Picosulfate plus Magnesium Citrate for Colonoscopy:
Norihiro Okamoto1, Shinwa Tanaka1,2, Hirohumi Abe1
1Division of Gastroenterology, Department of Internal Medicine, Graduate School of Medicine, Kobe University, Kobe, Japan.
Introduction:
Sodium picosulfate plus magnesium citrate is a bowel preparation agent with high patient acceptability. However, it is unclear which patients are more likely to have inadequate bowel preparation when using this agent. This study aimed to identify the risk factors for inadequate bowel preparation when using sodium picosulfate plus magnesium citrate for colonoscopy and to develop a scoring model to predict which patients will have inadequate bowel preparation.
Methods:
A total of 350 Japanese patients were enrolled from June 2021 to April 2022. Data on patient background, details of colonoscopy, and satisfaction assessment questionnaire results were prospectively collected. The scoring model for inadequate bowel preparation was developed based on multiple logistic regression analyses, and its performance was internally validated using bootstrapping.
Results:
Adequate bowel preparation was obtained in 295 patients (84.3%); 335 (95.7%) were able to ingest the drug without difficulty. The scoring model consisted of five independent risk factors and points of risk scores were assigned to each one as follows: American Society of Anesthesiologists physical status III (1 point), diabetes comorbidities (5 points), use of laxatives (4 points), no defecation once in a day (2 points), and drug use for mental disorder (6 points). The C-statistics of the scoring system for inadequate bowel preparation was 0.75.
Discussion:
We identified five risk factors for inadequate bowel preparation when using sodium picosulfate plus magnesium citrate regimen and developed a scoring model for inadequate bowel preparation with satisfactory discrimination and calibration.
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Endoscopic Procedures II: Colonoscopy
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Lower GI Series: Barium Enema
Procedure Details
The examination begins by inserting a lubricated rectal tube into the patient's rectum to administer a radiopaque barium solution. The barium flow is carefully...
Assessment of the Rectum and Anus
Rectal Inspection
Begin by inspecting the perianal and anal areas for color, texture, rashes,...