Forty-Year Trends in Cardiac Implantable Electronic Device Infective Endocarditis
Marta Hernández-Meneses1, Jaume Llopis2, Elena Sandoval3
1Infectious Diseases Department, Hospital Clinic, Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), University of Barcelona, Barcelona, Spain.
Background:
Studies investigating cardiac implantable electronic device infective endocarditis (CIED-IE) epidemiological changes and prognosis over long periods of time are lacking.
Methods:
Retrospective single cardiovascular surgery center cohort study of definite CIED-IE episodes between 1981-2020. A comparative analysis of two periods (1981-2000 vs 2001-2020) was conducted to analyze changes in epidemiology and outcome over time.
Results:
One-hundred and thirty-eight CIED-IE episodes were diagnosed: 25 (18%) first period and 113 (82%) second. CIED-IE was 4.5 times more frequent in the second period, especially in implantable cardiac defibrillators. Age (63 [53-70] vs 71 [63-76] years, P < .01), comorbidities (CCI 3.0 [2-4] vs 4.5 [3-6], P > .01), nosocomial infections (4% vs 15.9%, P = .02) and transfers from other centers (8% vs 41.6%, P < .01) were significantly more frequent in the second period, as were methicillin-resistant coagulase-negative staphylococcal (MR-CoNS) (0% vs 13.3%, P < .01) and Enterococcus spp. (0% vs 5.3%, P = .01) infections, pulmonary embolism (0% vs 10.6%, P < .01) and heart failure (12% vs 28.3%, p < .01). Second period surgery rates were lower (96% vs 87.6%, P = .09), and there were no differences in in-hospital (20% vs 11.5%, P = .11) and one-year mortalities (24% vs 15%, P = .33), or relapses (8% vs 5.3%, P = 0.65). Multivariate analysis showed Charlson index (hazard ratios [95% confidence intervals]; 1.5 [1.16-1.94]) and septic shock (23.09 [4.57-116.67]) were associated with a worse prognosis, whereas device removal (0.11 [.02-.57]), transfers (0.13 [.02-0.95]), and second-period diagnosis (0.13 [.02-.71]) were associated with better one-year outcomes.
Conclusions:
CIED-IE episodes increased more than four-fold during last 40 years. Despite CIED-IE involved an older population with more comorbidities, antibiotic-resistant MR-CoNS, and complex devices, one-year survival improved.
Related Concept Videos
Endocarditis I: Introduction
Endocarditis II: Clinical Features of Infective Endocarditis
Endocarditis III: Medical Management
Endocarditis IV: Nursing Management
Healthcare Associated Infections I: Iatrogenic, Exogenic and Endogenic
HAIs significantly increase the cost of health care. Extended stays in healthcare institutions, increased disability, increased costs of medications, including specialized antibiotics, and prolonged recovery times add to the patient's expenses and the healthcare institution and funding bodies.
Factors Affecting the Risk of Infection
The integrity and count of the white blood cells help the body resist pathogens and fight infection. When impaired, it reduces the body's resistance to pathogens. The acidic pH levels of the gastrointestinal, genitourinary tracts, and skin...