Assessing jugular venous compliance with optical hemodynamic imaging by modulating intrathoracic pressure
Robert Amelard1,2, Nyan Flannigan2, Courtney A Patterson2
1University Health Network, KITE-Toronto Rehabilitation Institute, Toronto, Ontario, Canada, Canada.
Significance:
The internal jugular veins (IJV) are critical cerebral venous drainage pathways that are affected by right heart function. Cardiovascular disease and microgravity can alter central venous pressure (CVP) and venous return, which may contribute to increased intracranial pressure and decreased cardiac output. Assessing jugular venous compliance may provide insight into cerebral drainage and right heart function, but monitoring changes in vessel volume is challenging.
Aim:
We investigated the feasibility of quantifying jugular venous compliance from jugular venous attenuation (JVA), a noncontact optical measurement of blood volume, along with CVP from antecubital vein cannulation.
Approach:
CVP was progressively increased through a guided graded Valsalva maneuver, increasing mouth pressure by 2 mmHg every 2 s until a maximum expiratory pressure of 20 mmHg. JVA was extracted from a 1-cm segment between the clavicle and midneck. The contralateral IJV cross-sectional area (CSA) was measured with ultrasound to validate changes in the vessel size. Compliance was calculated using both JVA and CSA between four-beat averages over the duration of the maneuver.
Results:
JVA and CSA were strongly correlated (median and interquartile range) over the Valsalva maneuver across participants (r = 0.986, [0.983, 0.987]). CVP more than doubled on average between baseline and peak strain (10.7 ± 4.4 vs. 25.8 ± 5.4 cmH2O; p < 0.01). JVA and CSA increased nonlinearly with CVP, and both JVA- and CSA-derived compliance decreased progressively from baseline to peak strain (49% and 56% median reduction, respectively), with no significant difference in compliance reduction between the two measures (Z = - 1.24, p = 0.21). Pressure-volume curves showed a logarithmic relationship in both CSA and JVA.
Conclusions:
Optical jugular vein assessment may provide new ways to assess jugular distention and cardiac function.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Venous Return
What is Venous Return?
Venous return refers to the rate at which blood flows back to the heart from the body's peripheral veins. It's an integral part of the circulatory system...
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessing Blood pressure in the Leg
Preparation: