Related Experiment Video
Updated: Aug 20, 2025

Optical Detection of E. coli Bacteria by Mesoporous Silicon Biosensors
Published on: November 20, 2013
Constructing hollow ZIF-8/CDs@MIPs fluorescent sensor from Osmanthus leaves to specifically recognize bovine
Xiqing Liu1, Le Tian1, Runping Ren1
1Jingdezhen Ceramic University, School of Materials Science and Engineering, Jingdezhen 333403, PR China.
Abstract:
To develop non-toxic, highly efficient and selective fluorescence sensors was a significance research. In this work, a novel hollow fluorescence sensor was designed with biomass carbon dots (CDs), ZIF-8 and molecularly imprinted polymers (MIPs) via aqueous polymerization. The results demonstrated such unique structure fluorescence sensor exhibited fast response time, excellent stability and highly selectively towards bovine hemoglobin (BHb). Even in a complex environment, the hollow fluorescence sensor (H-ZIF-8/CDs@MIPs) still has a good recognition effect on BHb. Under an optimized condition, the hollow fluorescence sensor was quenched linearly with BHb concentration in the range of 0.058-4.5 μM with the detection limit of 15.6 nM. In addition, a possible quenching mechanism of hollow fluorescence towards BHb was confirmed resonance energy transfer (FRET). In the actual application process, the hollow fluorescence sensor showed a better detection performance towards BHb with the recoveries ranged of 98.6-101.1 %. This work provided a strategy to design green and unique hollow fluorescence sensor for practical application.