Related Experiment Video
Updated: Aug 20, 2025

Oxygenation-sensitive Cardiac MRI with Vasoactive Breathing Maneuvers for the Non-invasive Assessment of Coronary Microvascular Dysfunction
Published on: August 17, 2022
Negative Stress Test Is Not Always Negative: Revisiting the Clinical Implications of Balanced Ischemia
Maddie Perdoncin1, Ebubechukwu Ezeh1, Utsab R Panta2
1Internal Medicine, Marshall University Joan C. Edwards School of Medicine, Huntington, USA.
Insights
Technetium (99mTc) sestamibi myocardial perfusion imaging is crucial for diagnosing coronary artery disease. However, this study highlights a case where it yielded false-negative results in a patient with severe disease and balanced perfusion deficits.
Area of Science:
- Cardiology
- Nuclear Medicine
- Diagnostic Imaging
Background:
- Myocardial perfusion imaging (MPI) using technetium (99mTc) sestamibi is a cornerstone in diagnosing coronary artery disease (CAD).
- Accurate MPI results guide critical clinical decisions, including revascularization strategies.
- The sensitivity of MPI can be limited, particularly in cases of balanced, diffuse, or multivessel coronary artery disease.
Observation:
- A case study involving a 45-year-old male patient with diagnosed severe coronary artery disease is presented.
- The patient underwent technetium (99mTc) sestamibi myocardial perfusion imaging as part of their diagnostic workup.
- Despite the presence of severe CAD, the MPI results were interpreted as normal, indicating a false-negative outcome.
Findings:
- The presented case demonstrates a false-negative myocardial perfusion imaging result in a patient with confirmed severe coronary artery disease.
- This false-negative finding occurred in the context of balanced perfusion deficits, a known limitation of MPI.
- The discrepancy between imaging findings and clinical severity underscores potential diagnostic challenges.
Implications:
- False-negative MPI results can lead to delayed diagnosis and suboptimal patient management for coronary artery disease.
- Clinicians must remain aware of the limitations of technetium (99mTc) sestamibi MPI, especially in patients with suspected or known multivessel disease.
- Further investigation or alternative diagnostic modalities may be warranted when clinical suspicion for CAD is high despite normal MPI findings.
Abstract:
Myocardial perfusion imaging with technetium (99mTc) sestamibi often aids in the diagnosis of coronary artery disease. This diagnostic tool is highly important in dictating future clinical decision-making and determining whether patients may benefit from revascularization. However, it is not completely sensitive and may be unreliable in diagnosing coronary artery disease in patients with balanced perfusion deficits. Here, we present the case of a 45-year-old male with severe coronary artery disease and false-negative myocardial perfusion imaging.
More Related Videos
14:09Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
Published on: March 21, 2013
18:11A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
Published on: December 28, 2012
Related Concept Videos
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Angina II: Classification
Angina III: Clinical Manifestations and Assessment
Acute Coronary Syndrome III: Diagnostic Studies
Acute Coronary Syndrome II: Pathophysiology and Clinical Manifestations
Psychoneuroimmunology: Cardiovascular Disease
A key area of focus in PNI is the relationship between stress and coronary...