Related Experiment Video
Updated: Aug 20, 2025

Calculating Heart Rate Variability from ECG Data from Youth with Cerebral Palsy During Active Video Game Sessions
Published on: June 5, 2019
Is There Agreement and Precision between Heart Rate Variability, Ventilatory, and Lactate Thresholds in Healthy
Letícia Nascimento Santos Neves1, Victor Hugo Gasparini Neto1, Igor Ziviani Araujo1
1Laboratory of Exercise Physiology (LAFEX), Physical Education and Sports Center, Federal University of Espírito Santo (CEFD-UFES), Vitória 29075-910, Brazil.
Abstract:
This study aims to analyze the agreement and precision between heart rate variability thresholds (HRVT1/2) with ventilatory and lactate thresholds 1 and 2 (VT1/2 and LT1/2) on a treadmill. Thirty-four male students were recruited. Day 1 consisted of conducting a health survey, anthropometrics, and Cardiopulmonary Exercise Test (CPx). On Day 2, after 48 h, a second incremental test was performed, the Cardiopulmonary Stepwise Exercise Test consisting of 3 min stages (CPxS), to determine VT1/2, LT1/2, and HRVT1/2. One-way repeated-measures ANOVA and effect size (ηp2) were used, followed by Sidak's post hoc. The Coefficient of Variation (CV) and Typical Error (TE) were applied to verify the precision. Bland Altman and the Intraclass Correlation Coefficient (ICC) were applied to confirm the agreement. HRVT1 showed different values compared to LT1 (lactate, RER, and R-R interval) and VT1 (V̇E, RER, V̇CO2, and HR). No differences were found in threshold 2 (T2) between LT2, VT2, and HRVT2. No difference was found in speed and V̇O2 for T1 and T2. The precision was low to T1 (CV > 12% and TE > 10%) and good to T2 (CV < 12% and TE < 10%). The agreement was good to fair in threshold 1 (VT1, LT1, HRVT1) and excellent to good in T2 (VT1, LT1, HRVT1). HRVT1 is not a valid method (low precision) when using this protocol to estimate LT1 and VT1. However, HRVT2 is a valid and noninvasive method that can estimate LT2 and VT2, showing good agreement and precision in healthy adults.
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Respiratory Volumes and Capacities
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...