Related Experiment Video
Updated: Aug 19, 2025

Noninvasive Determination of Vortex Formation Time Using Transesophageal Echocardiography During Cardiac Surgery
Published on: November 28, 2018
A Pilot Study of Heart Rate Variability Synchrony as a Marker of Intraoperative Surgical Teamwork and Its Correlation
Katarzyna Powezka1, Allan Pettipher2, Apit Hemakom2
1Imperial Vascular Unit, Imperial College Healthcare NHS Trust, London W2 1NY, UK.
Abstract:
Objective: Quality of intraoperative teamwork may have a direct impact on patient outcomes. Heart rate variability (HRV) synchrony may be useful for objective assessment of team cohesion and good teamwork. The primary aim of this study was to investigate the feasibility of using HRV synchrony in surgical teams. Secondary aims were to investigate the association of HRV synchrony with length of procedure (LOP), complications, number of intraoperative glitches and length of stay (LOS). We also investigated the correlation between HRV synchrony and team familiarity, pre- and intraoperative stress levels (STAI questionnaire), NOTECHS score and experience of team members. Methods: Ear, nose and throat (ENT) and vascular surgeons (consultant and registrar team members) were recruited into the study. Baseline demographics including level of team members’ experience were gathered before each procedure. For each procedure, continuous electrocardiogram (ECG) recording was performed and questionnaires regarding pre- and intraoperative stress levels and non-technical skills (NOTECHS) scores were collected for each team member. An independent observer documented the time of each intraoperative glitch. Statistical analysis was conducted using stepwise multiple linear regression. Results: Four HRV synchrony metrics which may be markers of efficient surgical collaboration were identified from the data: 1. number of HRV synchronies per hour of procedure, 2. number of HRV synchrony trends per hour of procedure, 3. length of HRV synchrony trends per hour of procedure, 4. area under the HRV synchrony trend curve per hour of procedure. LOP was inversely correlated with number of HRV synchrony trends per hour of procedure (p < 0.0001), area under HRV synchrony trend curve per hour of procedure (p = 0.001), length of HRV synchrony trends per hour of procedure (p = 0.002) and number of HRV synchronies per hour of procedure (p < 0.0001). LOP was positively correlated with: FS (p = 0.043; R = 0.358) and intraoperative STAI score of the whole team (p = 0.007; R = 0.493). Conclusions: HRV synchrony metrics within operating teams may be used as an objective marker to quantify surgical teamwork. We have shown that LOP is shorter when the intraoperative surgical teams’ HRV is more synchronised.
More Related Videos
04:58Reduced Procedure Time and Variability with Active Esophageal Cooling During Radiofrequency Ablation for Atrial Fibrillation
Published on: August 25, 2022
08:12Calculating Heart Rate Variability from ECG Data from Youth with Cerebral Palsy During Active Video Game Sessions
Published on: June 5, 2019
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Special considerations while measuring pulse
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...