Related Experiment Video
Updated: Aug 19, 2025

Qualitative Identification of Carboxylic Acids, Boronic Acids, and Amines Using Cruciform Fluorophores
Published on: August 19, 2013
N-Methylfulleropyrrolidine-Based Multimode Sensor for Determination of Butoconazole Nitrate
Bianca-Maria Ţuchiu1,2, Raluca-Ioana Stefan-van Staden1,2, Jacobus Koos Frederick van Staden1
1Laboratory of Electrochemistry and PATLAB, National Institute of Research for Electrochemistry and Condensed Matter, 202 Splaiul Independentei Str., 060021Bucharest-6, Romania.
Abstract:
A multimode sensor (a sensor responding simultaneously to more than one mode, e.g., stochastic mode, amperometric mode, voltammetric mode) based on graphite paste modified with N-methylfulleropyrrolidine was proposed for the determination of butoconazole nitrate in its pharmaceutical formulation. The stochastic mode and square wave voltammetry mode were applied for the determinations. Both the stochastic mode and square wave voltammetry mode were applied for a qualitative and quantitative assay of butoconazole nitrate. The sensor can be used between 1.68 × 10-6 and 1.68 × 104 μmol L-1 when the stochastic mode is used and between 0.168 and 16.80 μmol L-1 when the square wave voltammetry mode is used. The multimode sensor was reliably used for the determination of butoconazole nitrate in its pharmaceutical formulation, Gynofort cream, the recorded recoveries being higher than 99.00%, with RSD (%) values of lower than 2.00%.