Related Experiment Video
Updated: Aug 19, 2025

Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
Variation and Outcomes of Hospital-Level High-Flow Nasal Cannula Usage Outside of Intensive Care
Jeffrey C Winer1, Elizabeth O Mertens2, Kristen Bettin1
1University of Tennessee Health Science Center, Le Bonheur Children's Hospital, Memphis, Tennessee.
Objectives:
Bronchiolitis is a viral respiratory infection that can progress to acute respiratory failure. This study evaluated the variability of hospital-wide high-flow nasal cannula (HFNC) usage outside of the ICU and its association with length of stay (LOS) and cost among pediatric patients admitted with bronchiolitis.
Methods:
This study included patients <2 years old admitted with bronchiolitis between September 1, 2018 and March 31, 2019. Hospitals were divided into groups based on the proportion of patients among those who had never been in the ICU who received HFNC (non-ICU HFNC usage [NIHU]). We performed hierarchical mixed-model linear regression to estimate the association of NIHU with LOS and cost using multiplicative ratios (MR) and 95% confidence intervals (CI), both (1) unadjusted and (2) after adjusting for demographics, clinical characteristics, and individual utilization of HFNC and/or ICU.
Results:
Unadjusted LOS was longer for patients in moderate (MR 1.14; 95% CI 1.11-1.18) and high (MR 1.26; 95% CI 1.22-1.30) NIHU hospitals. Adjusted LOS was longer in moderate (MR 1.03; 95% CI 1.01-1.06), and high (MR 1.08; 95% CI 1.05-1.11) NIHU hospitals. Unadjusted total cost was higher for patients in moderate (MR 1.20; 95% CI 1.16-1.25) and high (MR 1.26; 95% CI 1.22-1.31) NIHU hospitals. Adjusted total cost was higher for patients in moderate (MR 1.05; 95% CI 1.03-1.08), and high (MR 1.05; 95% CI 1.02-1.08) NIHU hospitals.
Conclusions:
In this study, increased NIHU is associated with increased LOS and total cost.
More Related Videos
09:36Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
07:52Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
Related Concept Videos
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Tracheostomy Decannulation
Description of the Procedure