Related Experiment Video
Updated: Aug 19, 2025

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Evaluation of patient doses for routine digital radiography procedures toward establishing an institutional
Sachith Welarathna1,2, Sivakumar Velautham3, Mihira Wanninayake4
1Postgraduate Institute of Science, University of Peradeniya, Peradeniya, Sri Lanka.
Abstract:
The present study was conducted as part of a comprehensive work to establish National Diagnostic Reference Levels (NDRLs) in Sri Lanka for the first time. DRLs can be used as an effective optimization tool for identifying unusually high or low patient doses during X-ray examinations. This study aims to propose institutional DRLs (IDRLs) by measuring the kerma-area product (KAP) of adult patients undergoing routine projection X-ray examinations. The median and the 75th percentile KAP values obtained were compared with that of the single institution KAP values reported from India and Greece. This descriptive cross-sectional study was conducted in a public hospital in Uva province, Sri Lanka, with 400 adult patients aged 18-87 years and weighing 58 ± 20 kg. The patient-specific information (age, sex, weight, and height) and corresponding exposure parameters (tube voltage and current-exposure time product) were obtained. The KAP values were measured, and descriptive statistics were utilized for data analysis. The median KAP values obtained were proposed as IDRLs. The IDRLs in Gy.cm2 were 0.23 for cervical spine anterior-posterior (AP), 0.19 for cervical spine lateral (LAT), 0.10 for chest posterior-anterior (PA), 0.06 for knee joint AP, 0.05 for knee joint LAT, 1.47 for KUB AP, 0.85 for lumbar spine AP, 1.97 for lumbar spine LAT, 0.29 for shoulder joint AP, 0.61 for skull PA, and 0.60 for skull LAT examinations. The maximum to minimum ratio of KAP values ranged from 2.4 for KUB AP to 6.3 for the cervical spine AP examinations. The median and the 75th percentile of most of the examinations were comparable to corresponding KAP values reported by the countries mentioned above, except for the skull PA and LAT examinations. Accordingly, interquartile ranges of exposure parameters are recommended for skull examinations to improve the optimization of patient doses.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Biological Effects of Radiation
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...