Related Experiment Video
Updated: Aug 19, 2025

Polytetrafluoroethylene PTFE as a Suture Material in Tendon Surgery
Published on: October 6, 2022
A Simple, Atraumatic Technique for Tendon Retrieval and Holding During Tendon Repair
Sourabh Shankar Chakraborty1,2,3, Ranjit Kumar Sahu1,2,3, Sudeshna Acharya1,2,3
1Sourabh Shankar Chakraborty, MCh, MNAMS, is from the Department of Burns and Plastic Surgery, South Eastern Railway Central Hospital, Kolkata, West Bengal, India.
Abstract:
In this report, we describe an atraumatic technique that can be used intraoperatively to hold and retrieve tendons during tendon repair procedures. To use this technique, the surgeon transfixes a 24-gauge needle 1.5-3.5 cm from the cut ends of the tendon and then uses a Kocher artery curved forceps to loop the end of the needle upon itself up to 180°. The surgeon can then use the needle to retrieve or hold the tendon during the repair. This simple, low-cost technique can be very effective and efficient when used in primary care centers, emergency departments, or other treatment areas.