Related Experiment Video
Updated: Aug 19, 2025

High-resolution Thermal Micro-imaging Using Europium Chelate Luminescent Coatings
Published on: April 16, 2017
Pit viper thermography: the pit organ used by crotaline snakes to detect thermal contrast has poor spatial resolution
Rulon W Clark1, George S Bakken1,2, Evan J Reed1
1Department of Biology, San Diego State University, San Diego, CA 92182, USA.
Abstract:
Pit vipers detect infrared radiation by means of temperature contrasts created on their pit organ membranes. Signals from pit organs integrate with visual signals in the optic tectum, leading to the conjecture that the facial pits operate as an extension of the visual system. Because similar mechanisms underlie thermal imaging technology, imagery from thermal cameras is often used to infer how pit vipers perceive their environment. However, pit organs lack a focusing mechanism, and biophysical models predict that pit organs should have poor spatial resolution compared with thermal imaging cameras. Nevertheless, behavioral studies occasionally suggest pits may have better resolution than predicted by biophysical models, indicating that processing in the central nervous system may improve imaging. To estimate the spatial resolution of the neural image informing behavior, we recorded snake responses evoked by targets moving across backgrounds composed of two contrasting temperatures with an average temperature equal to the target temperature. An unresolved background would appear uniform; thus, the target would be detectable only if the background pattern were resolved. Western rattlesnakes (Crotalus oreganus) displayed no statistically significant responses to targets presented in front of patterned backgrounds, regardless of the temperature contrasts or spatial frequencies within the background, but responded strongly to targets presented in front of homogeneous backgrounds. We found no evidence that the pit organ system can resolve spatial details subtending an angle of 9 deg or less. We discuss the implications of these results for understanding pit organ function in ecologically relevant habitats with thermal heterogeneity.
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Thermosensation

