Related Experiment Video
Updated: Aug 19, 2025

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
Published on: December 18, 2016
Adaptive Training: A New Method to Improve the Image Quality of Abdominal Magnetic Resonance Imaging
Fu Kun1, Ran Qisheng1, Guo Guang-Kuo1
1Department of Radiology, Army Medical Center of PLA, Chong Qing, China.
Background:
In abdominal magnetic resonance imaging (MRI), the late hepatic arterial phase is particularly important for the diagnosis of hepatocellular carcinoma (HCC). However, poor patient compliance with breath-hold imaging acquisition protocols and the administration of the liverspecific contrast agent gadolinium ethoxybenzyl-diethylenetriaminepentaacetic acid (Gd-EOB-DTPA) increases the motion artifacts that degrade the quality of the images making it more difficult to interpret the images.
Objective:
This study aimed to evaluate the role of adaptive respiratory training in improving the quality of the MRI by reducing the motion artifacts and improving the signal intensity from the regions of interest (ROI) in the late hepatic arterial phase.
Methods:
A total of 120 patients who underwent an abdominal MRI between 2021 to 2022 to assess for the liver disease were included in the study. These patients were divided into two groups: the experimental group and the control group. The patients in the experimental group received adaptive training. The incidence of motion artifacts and the signal intensity in the late hepatic arterial phase within the abdominal aorta, hepatic artery, splenic artery, and hepatic parenchyma between the experimental group and the control group were compared.
Results:
The incidence of motion artifacts in the experimental group was significantly reduced by 28.3% (p = 0.001, Chi-square value = 12.079). In the late hepatic arterial phase, the signal intensity of the abdominal aorta, the hepatic artery, the splenic artery, and the hepatic parenchyma increased by 7.3%, 27.4%, 29.5%, and 6.9%, respectively.
Conclusion:
Adaptive respiratory training reduced the incidence of motion artifacts and improved the signal intensity for various ROI. The improved image quality could potentially facilitate image interpretation and reduce the number of repeat MRI scans.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System IV: CMRI