Purpose:
To evaluate image quality and diagnostic accuracy of buccal bone thickness assessment in maxillary and mandibular anterior region using cone-beam computed tomography (CBCT) and 3-dimensional double-echo steady-state (DESS) MRI for preoperative planning of immediate dental implants in healthy individuals.
Methods:
One hundred and twenty teeth in 10 volunteers were retrospectively evaluated for image quality and artifacts using Likert scale (4 = excellent to 0 = decreased). Buccal bone thickness was measured at three measurement points (M1 = 2 mm from the cementoenamel junction, M2 = middle of the root, and M3 = at the root apex) for each tooth in the maxillary (13-23) and the mandibular anterior region (33-43). Descriptive statistics and two-way ANOVA with Tukey's Post-hoc test were performed to evaluate the significant differences (α = 0.05) between both imaging modalities.
Results:
Image quality showed little to no artifacts and enabled confident diagnostic interpretation (CBCT (3.72 ± 0.46); MRI (3.65 ± 0.49)), with no significant differences between both imaging modalities (p > 0.05). Regarding the assessment of buccal bone thickness at M1-M3 for the teeth 13-23 and 33-43, no significant differences were noted (p > 0.05). MRI demonstrated slight, nonsignificant overestimation of thickness with the canines having mainly a thick buccal bone wall, where thin buccal wall was evident for the central incisors.
Conclusion:
Black bone MRI sequences, such as 3D-DESS MRI, for immediate implant planning provided confidential diagnostic accuracy in bone thickness assessment without significant disadvantages compared to CBCT. Thus, the implementation of no-dose protocols for dental rehabilitation using an immediate loading approach seems promising and could further improve the treatment strategy for dental rehabilitation.