Curtain Flow Column: Optimization of Efficiency and Sensitivity
Published on: June 12, 2016
An improved design of the fused silica capillary flow cell for absorbance detection in microcolumn liquid
Zuzana Gogaľová1, Vladislav Kahle1, Jozef Šesták1
1Institute of Analytical Chemistry of the Czech Academy of Sciences, Veveří 967/97, Brno, Czech Republic.
Abstract:
Efficient absorbance detection of a low-volume chromatography peak is a difficult task. In this work, an improved design of the fused silica capillary flow cell for absorbance detection in microcolumn liquid chromatography is described. The cell was fabricated from 0.15 mm I. D. fused silica capillary and silica optical fibres. Optical fibres were fully integrated into the cell design and enabled a convenient and effective connection of the cell with the light source and light detector (265 nm UV LED and photodiode in this work). Manufactured cells covered the range of physical lengths 3.1-9.9 mm (55-175 nL) and were used without any focusing optics and slits. Baseline noise was typically below 0.05 mAU and the effective optical path determined in the experiments was 83-97% of the cell's physical length. The level of stray (parasitic) light indicated by a 1% deviation from linearity at 1.7 AU was 0.08% only. The proposed cell design was found to be moderately susceptible to the refractive index change (20-35 mAU baseline change in 5-95% (v/v) gradient of acetonitrile or methanol in a mixture with water, G index up to 4 AU·s/RIU). Manufactured cells were finally applied for absorbance detection of components of test the mixture eluted off 0.3 mm I. D. microcolumn. 9.9 mm cell (175 nL) with an effective optical path of 8.9 mm exhibited contribution to the broadening of chromatography peak comparable with commercial 6 mm (80 nL) rectangular flow cell.
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
High-Performance Liquid Chromatography: Instrumentation
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
High-Performance Liquid Chromatography: Elution Process
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...