Postoperative prosthetic mitral valve occlusion due to left atrial thrombus during veno-arterial extracorporeal
Naoto Kiuchi1, Yusuke Seino2,3, Mai Yamamoto1
1Department of Anesthesiology, Nihon University School of Medicine, 30-1 Kamicho Oyaguchi, Itabashi-ku, Tokyo, Japan.
Background:
Anticoagulation using heparin is generally used to prevent thrombus formation during mechanical circulatory support, such as veno-arterial extracorporeal membrane oxygenation (VA-ECMO). However, during the early period following cardiac surgery, anticoagulation becomes more difficult due to the greater risk of critical bleeding complications.
Case Presentation:
A 71-year-old man presented with acute prosthetic valve occlusion caused by left atrial thrombus formation and bioprosthetic valve thrombosis during peripheral VA-ECMO following mitral valve replacement (MVR) despite continuous heparin administration and loading of antiplatelet agents. The VA-ECMO flow rate decreased 10 h after the intensive care unit (ICU) admission after MVR. Exploratory transesophageal echocardiography (TEE) examination revealed a left atrial thrombus, prosthetic valve obstruction by the thrombus, and an intrapericardial hematoma.
Conclusions:
Intracardiac thrombus formation might occur during VA-ECMO despite appropriate anticoagulation and loading of antiplatelet agents. Exploratory TEE examination was helpful in the detection of intra-atrial thrombus formation after cardiac surgery and surgical decision-making.