Left ventricular speckle tracking echocardiographic evaluation before and after TAVI
Vasiliki Tsampasian1, Vasileios Panoulas2,3,4, Richard J Jabbour2,3
1Hammersmith Hospital, Imperial College Healthcare NHS Trust, London, UK. tsampasian@doctors.org.uk.
Transcatheter aortic valve implantation (TAVI) improves left ventricular (LV) function and global longitudinal strain (GLS), particularly in patients with baseline LV dysfunction. Both Edwards S3 and Evolut R valves showed similar LV functional improvements, though Evolut R had more aortic regurgitation.
Area of Science:
- Cardiology
- Cardiac Surgery
- Medical Imaging
Background:
- Transcatheter aortic valve implantation (TAVI) is a key treatment for severe aortic stenosis.
- Assessing left ventricular (LV) function post-TAVI is crucial for understanding outcomes.
- Global longitudinal strain (GLS) offers a sensitive measure of LV function beyond ejection fraction (EF).
Purpose of the Study:
- To evaluate changes in LV function using conventional echocardiography and GLS after TAVI.
- To compare the effectiveness of Edwards S3 and Evolut R valves on LV function and remodeling.
- To identify predictors of LV functional improvement post-TAVI.
Main Methods:
- Retrospective analysis of 85 patients undergoing TAVI between 2015-2018.
- Exclusion of patients with coronary artery disease or atrial fibrillation.
- Assessment of LV function via conventional echocardiographic parameters and GLS pre- and post-TAVI.
Main Results:
- TAVI led to significant early improvement in GLS (P=0.01) but not EF (P=0.09).
- LV mass decreased, particularly in patients with baseline LV hypertrophy (P < 0.001).
- No significant differences in LV function improvement or remodeling were observed between Edwards S3 and Evolut R valves (P=0.14).
Conclusions:
- TAVI promotes reverse remodeling and enhances GLS, especially in patients with impaired baseline LV function.
- Both Edwards S3 and Evolut R valves yield comparable improvements in LV function post-TAVI.
- A higher incidence of aortic regurgitation was noted with the Evolut R valve compared to the Edwards S3.
Related Concept Videos
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...