Related Experiment Video
Updated: Aug 18, 2025

Quantitative Analysis of Vacuum Induction Melting by Laser-induced Breakdown Spectroscopy
Published on: June 10, 2019
Near-the-Line Steel Slag Analysis Using Laser-Induced Breakdown Spectroscopy: Traditional Univariate Versus Machine
Jonas Peterson1, Melina Gilbert-Gatty1, Krister Ekström1
1Department of Analytical Process Monitoring, Swerim AB, Kista, Sweden.
Abstract:
This work is focused on rapid quantitative analysis of slag in the steel industry for improved process control. The novel approach in this work is a direct comparison of two methods to calibrate and quantify spectral data from the slags. Calibration was first done with the most prevalent method in quantitative optical emission spectroscopy (OES) of solids, the univariate ratio method. The second method is an advanced multivariate analysis (MVA) algorithm termed Elastic Net, allowing to include several lines for each element in the calibration functions. In both methods, the output is mass fraction ratios of the analyte element (or compound) to a matrix element (compound). The actual mass fractions of each compound are calculated by sum normalization assuming the matrix to make up the difference up to 100%. The metric used to evaluate the performance of the methods in terms of accuracy is the parameter σrel calculated as the ratio of the root mean square (RMS) deviation from values obtained by X-ray fluorescence (XRF) divided by the average mass fraction of the compound, expressed in percent. A bit surprising, the main outcome of the comparison is that there is very little difference in the performance of the two methods. One exception is the analysis of MgO, where the elastic net gives significantly better accuracy. Presumably, this is due to the use of multiple lines for Mg to build the calibration function. This is very encouraging, since MgO is a major compound in most slags that needs to be determined accurately. It is suggested to improve accuracy further by means of separate calibrations for a limited number of slag types.
More Related Videos
10:17Laser-induced Breakdown Spectroscopy: A New Approach for Nanoparticle's Mapping and Quantification in Organ Tissue
Published on: June 18, 2014
08:53Dependence of Laser-induced Breakdown Spectroscopy Results on Pulse Energies and Timing Parameters Using Soil Simulants
Published on: September 23, 2013
Related Concept Videos
Atomic Emission Spectroscopy: Lab
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Atomic Emission Spectroscopy: Overview
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...