Related Experiment Video
Updated: Aug 17, 2025

Author Spotlight: Automated Deep Brain Stimulation for Parkinson's Disease - Exploring the Possibilities and Challenges of Home Monitoring
Published on: July 14, 2023
Robust Pulse Rate Measurements from Facial Videos in Diverse Environments
1Department of Electrical and Computer Engineering, Sungkyunkwan University, 2066 Seobu-ro, Jangan-gu, Suwon-si 16419, Republic of Korea.
Abstract:
Pulse wave and pulse rate are important indicators of cardiovascular health. Technologies that can check the pulse by contacting the skin with optical sensors built into smart devices have been developed. However, this may cause inconvenience, such as foreign body sensation. Accordingly, studies have been conducted on non-contact pulse rate measurements using facial videos focused on the indoors. Moreover, since the majority of studies are conducted indoors, the error in the pulse rate measurement in outdoor environments, such as an outdoor bench, car and drone, is high. In this paper, to deal with this issue, we focus on developing a robust pulse measurement method based on facial videos taken in diverse environments. The proposed method stably detects faces by removing high-frequency components of face coordinate signals derived from fine body tremors and illumination conditions. It optimizes for extracting skin color changes by reducing illumination-caused noise using the Cg color difference component. The robust pulse wave is extracted from the Cg signal using FFT-iFFT with zero-padding. It can eliminate signal-filtering distortion effectively. We demonstrate that the proposed method relieves pulse rate measurement problems, producing 3.36, 5.81, and 6.09 bpm RMSE for an outdoor bench, driving car, and flying drone, respectively.
More Related Videos
Related Concept Videos
Special considerations while measuring pulse
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:

