Related Experiment Video
Updated: Aug 17, 2025

A Detailed Protocol for Perspiration Monitoring Using a Novel, Small, Wireless Device
Published on: November 24, 2016
Graphene-Enhanced Polydimethylsiloxane Patch for Wearable Body Temperature Remote Monitoring Application
Jie Huang1,2, Daqing Huang1
1College of Electronic and Information Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210024, China.
Abstract:
In this work, we designed and implemented a wearable body temperature monitoring device, which was constructed by a graphene-enhanced polydimethylsiloxane patch and a temperature measurement chip. The body temperature patch adopts a completely flexible solution in combination with near field communication component, which provides the advantages of passive wireless, overall flexibility, and being comfortable to wear. The whole device can be bent and stretched in conformal contact with skin. In order to improve the temperature conduction ability of the patch and make the patch data more accurate, we adopted graphene nanoplates to improve the thermal conductivity of polydimethylsiloxane patch with a significant thermal conductivity increase of 23.8%. With the combination of hollow sandwich structure and small dimension. it will reduce the uncomfortable situation of wearing the device for extended periods and can be served to monitor the human body temperature for a long time. Ultimately, this device is combined with a reading software for analyzing and processing on a smart mobile terminal. The real-time and past temperature range can be a pre-warning; meanwhile, the historical data can be traced and analyzed. Therefore, this device can be utilized in multiple human body temperature measurement scenarios and complex public health situations.
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...