Related Experiment Video
Updated: Aug 17, 2025

Sensitivity Enhancement of Soft Capacitive Pressure Sensors Using a Solvent Evaporation-Based Porosity Control Technique
Published on: March 24, 2023
Analysis and Correction of Measurement Error of Spherical Capacitive Sensor Caused by Assembly Error of the Inner
Tianxiang Ma1, Shengqi Yang2,3, Yongsen Xu2
1Information and Communication Engineering, School of Electronic and Information Engineering, Changchun University of Science and Technology, Changchun 130022, China.
Abstract:
The ball joint is a multi-degree-of-freedom transmission pair, if it can replace the inner frame in the aviation photoelectric pod to carry the optical load, which will greatly simplify the system structure of the photoelectric pod and reduce the space occupied by the inner frame. However, installation errors in ball joint siting introduce nonlinear errors that are difficult to correct and two degree of freedom angular displacement of the ball joint is difficult to detect, which limits application in the precision control of two degrees of freedom systems. Studies of spherical capacitive sensors to date have not tested sensors for use in an inner frame stabilisation mechanism nor have they analysed the influence of installation error on sensor output. A two-axis angular experimental device was designed to measure the performance of a ball joint capacitive sensor in a frame stabilisation mechanism in an aeronautical optoelectronic pod, and a mathematical model to compensate for ball joint capacitive sensor installation error was created and tested. The experimental results show that the resolution of the capacitive sensor was 0.02° in the operating range ±4°, the repeatability factor was 0.86%, and the pulse response time was 39 μs. The designed capacitive sensor has a simple structure, high measurement accuracy, and strong robustness, and it can be integrated into ball joint applications in the frames of aeronautical photoelectric pods.
Related Concept Videos
Spherical and Cylindrical Capacitor
Conventionally, considering the symmetry, the electric field between the concentric shells of a spherical capacitor is directed radially outward. The magnitude of the field,...
Distance Corrections
Random and Systematic Errors
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Uncertainty in Measurement: Reading Instruments
Common Leveling Mistakes and Errors

