Related Experiment Video
Updated: Aug 17, 2025

Author Spotlight: Advancing Biopsy Techniques with Transesophageal Ultrasound
Published on: November 21, 2023
Randomized trial of contrast-enhanced harmonic guidance versus fanning technique for EUS-guided fine-needle biopsy
Yu-Ting Kuo1, Yu-Long Chu2, Weng-Fai Wong3
1Division of Endoscopy, Department of Integrated Diagnostics & Therapeutics, National Taiwan University Hospital, National Taiwan University, Taipei, Taiwan; Department of Internal Medicine, College of Medicine, National Taiwan University, Taipei, Taiwan.
Background And Aims:
For EUS-guided fine-needle biopsy sampling (EUS-FNB) of solid pancreatic lesions (SPLs), the role of sampling strategy between targeted biopsy sampling and wide sampling has not been reported. This study aimed to investigate the benefits of the 2 sampling techniques on EUS-FNB using rapid on-site evaluation.
Methods:
Patients with SPLs were prospectively enrolled and randomly assigned (1:1) to undergo EUS-FNB using either contrast guidance or the fanning technique. The primary outcome was the total number of passes required to establish a diagnosis, and secondary outcomes were overall diagnostic accuracy and adverse event rates.
Results:
One hundred eighteen patients were enrolled from February 2019 to January 2021, with 59 patients assigned to each group. There was no significant difference in the total number of passes required to establish a diagnosis between the contrast and fanning groups (median, 1 [interquartile range, 1-1] vs 1 [interquartile range, 1-2], respectively; P = .629). The sensitivity, specificity, and diagnostic accuracy in the contrast group was 100%, 66.7%, and 98.3% and in the fanning group 100%, 100%, and 100%, respectively (P = 1). An SPL <4 cm (odds ratio, 2.47; 95% confidence interval, 1.05-5.81; P = .037) and macroscopic visible core length >1 cm (odds ratio, 2.89; 95% confidence interval, 1.07-7.84; P = .037) were independently associated with increased cytologic and histologic accuracy.
Conclusions:
The diagnostic accuracy of EUS-FNB with the fanning technique for SPLs was comparable with the contrast guidance technique. Without additional cost, EUS-FNB with the fanning technique may be preferred for SPLs. (Clinical trial registration number: NCT04924725.).