Related Experiment Video
Updated: Aug 17, 2025

Optimized Griess Reaction for UV-Vis and Naked-eye Determination of Anti-malarial Primaquine
Published on: October 11, 2019
Voltammetric approach for pharmaceutical samples analysis; simultaneous quantitative determination of resorcinol and
Ebrahim Nabatian1,2, Mahdi Mousavi2, Mostafa Pournamdari3
1Student Research Committee, Kerman University of Medical Sciences, Kerman, Iran.
Abstract:
A simple and precise analytical approach developed for single and simultaneous determination of resorcinol (RC) and hydroquinone (HQ) in pharmaceutical samples using carbon paste electrode (CPE) modified with 1-Ethyl-3-methylimidazolium tetrafluoroborate as ionic liquid and ZnFe2O4 nanoparticle. A significant enhancement in the peak current and sensitivity of the proposed sensor observed by using modifiers in the composition of working electrode compared to bare CPE which is in accordance with the results obtained from electrochemical impedance spectroscopy investigations. Electrochemical investigations revealed a well-defined irreversible oxidation peak for RC over a wide concentration range from 3.0 µM to 500 µM in 0.1 M phosphate buffer solution (pH 6.0) with the linear regression equations of Ip (µA) = 0.0276 CRC (µM) + 0.5508 (R2 = 0.997). The limit of detection and quantification for RC analysis were found to be 1.46 µM and 4.88 µM, respectively. However, the obtained SW voltammograms for simultaneous determination of RC and HQ exhibited a desirable peak separation of about 360 mV potential difference and a satisfactory linear response over the range of 50-700 µM and 5-350 µM with the favorable correlation coefficient of 0.991 and 0.995, respectively. The diffusion coefficient (D) of RC and the electron transfer coefficient (α) at the surface of ZnFe2O4/NPs/IL/CPE estimated to be 2.83 × 10- 4 cm s- 1 and 0.76. The proposed sensor as a promising and low-cost method successfully applied for determination of RC in commercial pharmaceutical formulations such as the resorcinol cream of 2% O/W emulsion available on the market with the recovery of 98.47 ± 0.04.
Related Concept Videos
Voltammetric Techniques: Linear-Scan (E vs Time)
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Voltammetric Techniques: Pulse Voltammetry
Voltammetric Techniques: Cyclic Voltammetry
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...

