Related Experiment Video
Updated: Jul 12, 2026

Cortical Source Analysis of High-Density EEG Recordings in Children
Published on: June 30, 2014
High-Density (HD) Scalp EEG Findings in "Benign" Childhood Epilepsy with Centrotemporal Spikes (BCECTS)
Sonal Bhatia1, Andrew Todd Ham2, Ekrem Kutluay3
1Department of Pediatrics, Division of Pediatric Neurology, Shawn Jenkins Children's Hospital and Medical University of South Carolina, Charleston, SC, USA.
Abstract:
Despite characteristic clinical and scalp EEG findings, BCECTS pathophysiology is unclear regarding involvement of large-scale neuronal networks. Higher number of scalp electrodes with HD-EEG may promote accurate localization of the cortical generators in BCECTS providing additional insight in those with neurocognitive problems. We aimed to determine the value of visual interpretation of topographical maps using 256 channels (when compared to standard 21 channel array) HD-EEG in BCECTS and attempted to source localize interictal discharges (IEDs) using Geosource 2 software. Patient records were reviewed for demographic, seizure, brain magnetic resonance imaging (MRI) details; scalp and HD-EEG findings. HD-EEG software was used to review raw EEG data (21 scalp EEG electrodes were compared to 256 HD-EEG electrodes); select, average, and source localize IEDs.Five BCECTS patients with HD-EEG were identified. Seizure onset age ranged from 5-11 years with 1-18 lifetime seizures; both focal (n = 3) and focal to bilateral tonic-clonic (n = 2). Neurocognitive co-morbidities noted in our cohort included attention deficit hyperactivity disorder, speech/developmental delay and a specific learning disorder. Scalp EEG showed typical findings with IEDs over the centrotemporal regions (bilateral n = 3; unilateral n = 2). Visualization and inspection of expanded coverage topographic maps with HD-EEG showed well-defined islands of maximum negativity and positivity of a dipole compared to conventional channels where boundary delineation was obscured. Further, HD-EEG localized IEDs/"spike-generator" to areas such as the pre-and post-central, middle-frontal and temporal gyrus, and the inferior parietal lobule. In BCECTS, HD-EEG may show affection for a broader neural network and may provide a better insight into the associated neurocognitive morbidities.
More Related Videos
10:22Interictal High Frequency Oscillations Detected with Simultaneous Magnetoencephalography and Electroencephalography as Biomarker of Pediatric Epilepsy
Published on: December 6, 2016
09:57Author Spotlight: Advancing Pediatric Epilepsy Surgery in Children Through Novel Biomarkers and Enhanced Localization
Published on: September 20, 2024