Hounsfield Units measured in low dose CT reliably assess vertebral trabecular bone density changes over two years in
Mary Lucy Marques1, Nuno Pereira da Silva2, Désirée van der Heijde3
1Department of Rheumatology, Leiden University Medical Center, Leiden, the Netherlands; Department of Rheumatology, Coimbra University Hospital, Coimbra, Portugal.
Objectives:
To describe low dose Computed Tomography (ldCT) Hounsfield Units (HU) two-year change-from-baseline values (expressing trabecular bone density changes) and analyse their inter-reader reliability per vertebra in radiographic axial spondyloarthritis (r-axSpA).
Methods:
We used 49 patients with r-axSpA from the multicentre two-year Sensitive Imaging in Ankylosing Spondylitis (SIAS) study. LdCT HU were independently measured by two trained readers at baseline and two years. Mean (standard deviation, SD) for the change-from-baseline HU values were provided per vertebra by reader. Intraclass correlation coefficients (ICC; absolute agreement, two-way random effect), Bland-Altman plots and smallest detectable change (SDC) were obtained. Percentages of vertebrae in which readers agreed on the direction of change and on change >|SDC| were computed.
Results:
Overall, 1,053 (98% of all possible) vertebrae were assessed by each reader both at baseline and two years. Over two years, HU mean change values varied from -23 to 28 and 29 for reader 1 and 2, respectively. Inter-reader reliability of the two-year change-from-baseline values per vertebra was excellent: ICC:0.91-0.99; SDC:6-10; Bland-Altman plots were homoscedastic, with negligible systematic error between readers. Readers agreed on the direction of change in 88-96% and on change >|SDC| in 58-94% of vertebrae, per vertebral level, from C3 to L5. Overall, similar results were obtained across all vertebrae.
Conclusion:
LdCT measurement of HU is a reliable method to assess two-year changes in trabecular bone density at each vertebra from C3-L5. Being reliable across all vertebrae, this methodology can aid the study of trabecular bone density changes over time in r-axSpA, a disease affecting the whole spine.