Generalized and wavelength-dependent temperature calibration function for multipoint regenerated fiber Bragg grating
Abstract:
A new calibration methodology for regenerated fiber Bragg grating (RFBG) temperature sensors up to 700 °C is proposed and demonstrated. A generalized, wavelength-dependent temperature calibration function is experimentally determined that describes the temperature-induced wavelength shifts for all RFBG sensor elements that are manufactured with the same fabrication parameters in the wavelength range from 1465 nm to 1605 nm. Using this generalized calibration function for absolute temperature measurements, each RFBG sensor element only needs to be calibrated at one reference temperature, representing a considerable simplification of the conventional calibration procedure. The new calibration methodology was validated with 7 RFBGs, and uncertainties were found to be compliant with those of Class 1 thermocouples (< ±1.5 K or < ±0.4% of the measured temperature). The proposed calibration technique overcomes difficulties with the calibration of spatially extended multipoint RFBG sensor arrays, where setting up an adequate calibration facility for large sensor fibers is challenging and costly. We assume that this calibration method can also be adapted to other types of FBG temperature sensors besides RFBGs. An accurate and practical calibration approach is essential for the acceptance and dissemination of the fiber-optic multipoint temperature sensing technology.
More Related Videos
10:52Design, Instrumentation and Usage Protocols for Distributed In Situ Thermal Hot Spots Monitoring in Electric Coils using FBG Sensor Multiplexing
Published on: March 8, 2020
04:41Optimized Sealing Process and Real-Time Monitoring of Glass-to-Metal Seal Structures
Published on: September 2, 2019
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...