Related Experiment Video
Updated: Aug 17, 2025

Calculating Heart Rate Variability from ECG Data from Youth with Cerebral Palsy During Active Video Game Sessions
Published on: June 5, 2019
Analysis of photoplethysmogram signal to estimate heart rate during physical activity using fractional fourier
Pankaj1, Ashish Kumar2, Aryaman Ashdhir3
1Department of Electronics and Communication Engineering, Bennett University, Greater Noida, India; Department of Electronics and Communication Engineering, Panipat Institute of Engineering and Technology, Panipat, India.
Background And Objective:
Acquiring accurate and reliable health information using a PPG signal in wearable devices requires suppressing motion artifacts. This paper presents a method based on the Fractional Fourier transform (FrFT) to effectively suppress the motion artifacts in a Photoplethysmogram (PPG) signal for an accurate estimation of heart rate (HR).
Methods:
By analyzing various PPG signals recorded under various physiological conditions and sampling frequencies, the proposed work determines an optimal value of the fractional order of the proposed FrFT. The proposed FrFT-based algorithm separates the motion artifacts component from the acquired PPG signal. Finally, the HR estimation accuracy during the strong motion artifact-affected windows is improved using a post-processing technique. The efficacy of the proposed method is evaluated by computing the root mean square error (RMSE).
Results:
The performance of the proposed algorithm is compared with methods in recent studies using test and training datasets from the IEEE Signal Processing Cup (SPC). The proposed method provides the mean absolute error of 1.88 beats per minute (BPM) on all twenty-three recordings.
Conclusions:
The proposed method uses the Fourier method in the fractional domain. A noisy signal is rotated into an intermediate plane between the time and frequency domains to separate the signal from the noise. The algorithm incorporates FrFT analysis to suppress motion artifacts from PPG signals to estimate HR accurately. Further, a post-processing step is used to track the HR for accurate and reliable HR estimation. The proposed FrFT-based algorithm doesn't require additional reference accelerometers or hardware to estimate HR in real-time. The noise and signal separation is optimum for a fractional order (a) value in the vicinity of 0.6. The optimized value of fractional order is constant irrespective of the physical activity and sampling frequency.
More Related Videos
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Fast Fourier Transform
The computational efficiency of the FFT becomes...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Special considerations while measuring pulse