Studying Dynamics of Mid-face Lifting During Hyaluronic Acid Filler Injection Using Ultrasound Imaging
Zhijin Li1, Zenan Xia1, Zikai Qiu1
1Department of Plastic Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shuaifuyuan No. 1, Dongcheng District, Beijing, 100730, China.
Background:
The ageing in the mid-face involves volume deficiency in multiple anatomical units, including the zygomatic arch, infraorbital region, medial and lateral cheek and nasolabial fold (NLF). Hyaluronic acid (HA) is extensively used in the minimally invasive procedures of mid-face rejuvenation.
Objectives:
MD CodesTM is proposed to perform combined treatment of multiple sites to reduce treatment variability and increase clinician success rates. Although the detailed procedure of this technique, aesthetic effects and complications have been disclosed, its anatomical information has yet to be discussed. This paper elaborated on the static and dynamic anatomical characteristics of MD CodesTM through cadaveric dissection and ultrasound imaging.
Methods:
Anatomical dissection and ultrasound imaging help us look back on the injection methods and anatomical principles of MD CodesTM.
Results:
The treatment is threefold: (1) the bolus injections, for lifting purposes, are performed at the most depressing point along the zygomatic arch, zygomatic eminence, the prominent optimal point in the zygomatic region, the most depressed point of upper NLF with 0.2-0.3 ml HA. (2) The linear injections, featuring facial contouring refinement, are performed at the deep fat pad of the medial cheek and infraorbital region with 0.4 ml HA. (3) The linear injections, featuring volume replacement, are performed at the subcutaneous fat layer of lateral cheek and NLF with 0.8 and 0.4 ml HA.
Conclusions:
MD CodeTM is led by the principle of "less dosage and better effect", and a special injection sequence is formulated based on the anatomical characteristics. Ultrasound is a useful tool to make for a dynamic anatomical understanding of MD CodeTM and visualize the anatomical information such as layers and thicknesses.
Level Of Evidence Iv:
This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
More Related Videos
07:05Ultrasound-guided Botulinum Toxin-A Injections: A Method of Treating Sialorrhea
Published on: November 9, 2016
07:38Real-time Monitoring of High Intensity Focused Ultrasound HIFU Ablation of In Vitro Canine Livers Using Harmonic Motion Imaging for Focused Ultrasound HMIFU
Published on: November 3, 2015
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Imaging Studies II: Ultrasonography