Related Experiment Video
Updated: Aug 16, 2025

Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
Replacement of a Calcified Aortic Valve in a Porcine Aortic Root with the Perceval Sutureless Bioprosthesis
Giosuè Falcetta1, Federico Del Re1, Stefano Pratali1
1Section of Cardiac Surgery, Department of Cardiac Thoracic and Vascular Surgery, University Hospital, Pisa, Italy.
Abstract:
We report a 79-year-old patient who had aortic valve replacement (AVR) using a porcine aortic root. Due to degeneration of the porcine aortic valve, he required reoperation during which a heavily calcified porcine root and aortic annulus prevented insertion of any traditional bioprosthesis. AVR was achieved using a sutureless bioprosthesis, combined with mitral valve replacement. The present case confirms the feasibility and advantages of using sutureless valve implantation in complex and high-risk redo procedures.