Molecularly imprinted nanoparticle-based assay (MINA) for microcystin-LR detection in water

Yadiris García1, Myleidi Vera2, Verónica A Jiménez1

  • 1Departamento de Ciencias Químicas, Facultad de Ciencias Exactas, Universidad Andres Bello, Sede Concepción, Autopista Concepción-Talcahuano 7100, Talcahuano, Chile. ygarcia@udec.cl.

The Analyst
|December 21, 2022
PubMed

Insights

A new Molecularly Imprinted Nanoparticle-Based Assay (MINA) effectively detects Microcystin-leucine-arginine (MC-LR) in water. This method offers a sensitive and selective tool for monitoring water safety and public health.

Area of Science:

  • Environmental Chemistry
  • Analytical Chemistry
  • Biotechnology

Background:

  • Microcystins (MCs) are toxic peptides from cyanobacteria, posing risks to human and animal health.
  • Microcystin-leucine-arginine (MC-LR) is the most prevalent and toxic MC variant.
  • Reliable detection methods for MC-LR are crucial for ensuring water safety.

Purpose of the Study:

  • To develop a simple and optimized Molecularly Imprinted Nanoparticle-Based Assay (MINA) for MC-LR detection.
  • To create robust and sensitive molecularly imprinted nanoparticles (MINs) for MC-LR recognition.
  • To evaluate the assay's performance for MC-LR detection in water samples.

Main Methods:

  • Preparation of MINs via solid-phase polymerization on APTES-conjugated glass beads.
  • Optimization of MIN immobilization and competitive assay conditions using HRP-MC-LR conjugate.
  • Evaluation of MINA performance, including limit of detection and selectivity.

Main Results:

  • The optimized MINA demonstrated preferential binding of MC-LR to immobilized MINs.
  • Achieved a limit of detection of 2.49 × 10⁻⁴ nmol L⁻¹ for MC-LR.
  • Exhibited selectivity for MC-LR over analogous microcystins (MC-RR, MC-YR) and low coefficients of variation (<10%).

Conclusions:

  • The developed MINA is a promising analytical tool for MC-LR detection below WHO safety limits.
  • MINs show potential for sensitive and selective detection of MC-LR in water.
  • Matrix effects in real water samples necessitate further development, including sample pretreatment methods.