Related Experiment Video
Updated: Aug 16, 2025

Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
Bi-criteria Pareto optimization to balance irradiation time and dosimetric objectives in proton arc therapy
Sophie Wuyckens1, Lewei Zhao2, Michael Saint-Guillain3
1UCLouvain, Molecular Imaging, Radiotherapy and Oncology (MIRO), Brussels, Belgium.
Abstract:
Objective. Proton arc therapy (PAT) is a new delivery technique that exploits the continuous rotation of the gantry to distribute the therapeutic dose over many angular windows instead of using a few static fields, as in conventional (intensity-modulated) proton therapy. Although coming along with many potential clinical and dosimetric benefits, PAT has also raised a new optimization challenge. In addition to the dosimetric goals, the beam delivery time (BDT) needs to be considered in the objective function. Considering this bi-objective formulation, the task of finding a good compromise with appropriate weighting factors can turn out to be cumbersome.Approach. We have computed Pareto-optimal plans for three disease sites: a brain, a lung, and a liver, following a method of iteratively choosing weight vectors to approximate the Pareto front with few points. Mixed-integer programming (MIP) was selected to state the bi-criteria PAT problem and to find Pareto optimal points with a suited solver.Main results. The trade-offs between plan quality and beam irradiation time (staticBDT) are investigated by inspecting three plans from the Pareto front. The latter are carefully picked to demonstrate significant differences in dose distribution and delivery time depending on their location on the frontier. The results were benchmarked against IMPT and SPArc plans showing the strength of degrees of freedom coming along with MIP optimization.Significance. This paper presents for the first time the application of bi-criteria optimization to the PAT problem, which eventually permits the planners to select the best treatment strategy according to the patient conditions and clinical resources available.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Radiation: Applications
The average...
Radiation Pressure: Problem Solving
The average value of the rate of momentum transfer divided by the absorbing area represents the average force...