Related Experiment Video
Updated: Aug 16, 2025

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
High-resolution 3D T2-weighted SPACE sequence with compressed sensing for the prostate gland: diagnostic performance
Moon Hyung Choi1, Young Joon Lee2, Seung Eun Jung1
1Department of Radiology, Eunpyeong St. Mary's Hospital, College of Medicine, The Catholic University of Korea, 1021 Tongil-Ro, Eunpyeong-Gu, Seoul, 03312, Republic of Korea.
Purpose:
To compare the diagnostic performance of high-resolution 3D T2-weighted imaging (T2WI) with compressed sensing (CS) sampling perfection with application-optimized contrasts using different flip angle evolution (SPACE) to that of conventional T2WI with turbo spin echo (TSE) in prostate MRI.
Materials And Methods:
This study evaluated 179 patients (mean age 69.1 ± 9.3) who underwent prostate biopsy after prostate prebiopsy MRI, including two sets of three-plane T2WI with TSE (thickness: 3 mm, scan time: 10 min 4 s) and CS SPACE (thickness: 0.6 mm, scan time: 4 min 55 s). Two radiologists evaluated two sets of images with the Prostate Imaging-Reporting and Data System (PIRADS) classification and determined the extraprostatic extension (EPE) of the lesion. The diagnostic performance to detect prostate cancer (PIRADS classification) and EPE was compared between the two T2WI sets.
Results:
Clinically significant cancer (CSC) was diagnosed in 103 patients (57.5%). Areas under the receiver operating characteristic curve of the PIRADS classification on both image sets with T2 TSE and T2 CS SPACE were higher than 0.7 and did not show significant differences for either radiologist (p > 0.05). EPE was confirmed in 25 of 70 patients underwent prostatectomy. For evaluating EPE on MRI, the sensitivity and specificity did not differ between the two T2WI sequences (p > 0.05).
Conclusion:
High-resolution 3D T2WI using CS SPACE, which was acquired within a shorter acquisition time than three-plane T2 TSE, showed comparable diagnostic performance to conventional T2 TSE for detecting CSC and evaluating EPE.
More Related Videos
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...