Related Experiment Video
Updated: Aug 16, 2025

In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
Evaluating the Image Quality of Neck Structures Scanned on Chest CT with Low-Concentration-Iodine Contrast Media
Jimin Kim1, Jee-Young Kim1, Se-Won Oh1
1Department of Radiology, Eunpyeong St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul 03312, Republic of Korea.
Background:
The purpose of this study was to investigate and compare the image quality of low-concentration-iodine (240 mgI/mL) contrast media (CM) and high-concentration-iodine (320 mgI/mL) CM according to the radiation dose.
Methods:
A total of 366 CT examinations were examined. Based on an assessment of quantitative and qualitative parameters by two radiologists, the quality was compared between Group A (low-concentration-iodine CM) and Group B (high-concentration-iodine CM) images of thyroid gland, sternocleidomastoid muscle (SCM), internal jugular vein (IJV), and common carotid artery (CCA). Another subgroup analysis compared Group a, (using ≤90 kVp in Group A), and Group b, (using ≥100 kVp in Group B) for finding the difference in image quality when the tube voltage is lowered.
Results:
Image quality did not differ between Groups A and B or between Groups a and b. The signal-to-noise ratio and contrast-to-noise ratio were significantly higher for Group B than Group A for the thyroid gland, IJV, and CCA. No statistical differences were found in the comparison of all structures between Groups a and b.
Conclusion:
There was no significant difference in image quality based on CM concentration with variable radiation doses. Therefore, if an appropriate CT protocol is applied, clinically feasible neck CT images can be obtained even using low-concentration-iodine CM.
More Related Videos
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Ultrasonography
During an ultrasonography procedure, a handheld device called...