Intense Pulsed Light for the Treatment of Dry Eye Owing to Meibomian Gland Dysfunction
Published on: April 1, 2019
Evaluating the Differences Between Fluorescein Tear Break-up Time and Noninvasive Measurement Techniques
Takashi Itokawa1, Takashi Suzuki, Shizuka Koh
1Department of Ophthalmology (T.I., T.S., Y.H.), Toho University, Tokyo, Japan; Ishizuchi Eye Clinic (T.S.), Ehime, Japan; and Department of Ophthalmology (S.K.), Osaka University, Osaka, Japan.
Noninvasive tear break-up time (BUT) measurements using interferometry and corneal topography show significant correlation with fluorescein BUT. These noninvasive methods offer effective tools for diagnosing dry eye disease.
Area of Science:
- Ophthalmology
- Optometry
- Tear film dynamics
Background:
- Dry eye disease is a prevalent condition affecting tear film stability.
- Accurate assessment of tear film stability is crucial for diagnosing dry eye.
- Traditional fluorescein tear break-up time (BUT) can be invasive and may influence tear film parameters.
Purpose of the Study:
- To compare fluorescein tear break-up time (BUT) with noninvasive BUT measurements.
- To evaluate noninvasive BUT methods using interferometry and corneal topography.
- To determine the diagnostic utility of noninvasive BUT in dry eye patients.
Main Methods:
- Investigated 34 dry eye patients and 16 non-dry eye subjects.
- Measured tear film stability using fluorescein BUT, noninvasive BUT (NIBUT)-DR1 (interferometry), and noninvasive keratographic BUT (NIKBUT) (corneal topography).
- Analyzed correlations and agreement (Bland-Altman) between methods; compared groups and determined diagnostic cut-off values.
Main Results:
- Fluorescein BUT significantly correlated with all noninvasive BUT parameters (NIBUT-DR1, NIKBUT-first, NIKBUT-average).
- Noninvasive BUT measurements yielded higher values than fluorescein BUT.
- Diagnostic cut-off values with varying sensitivities and specificities were established for noninvasive methods.
Conclusions:
- Noninvasive tear film stability measurements are significantly correlated with fluorescein BUT.
- Noninvasive BUT methods demonstrate potential as effective diagnostic tools for dry eye.
- These methods provide valuable, objective data for assessing tear film integrity.
More Related Videos
07:54Fluorescence Recovery after Merging a Droplet to Measure the Two-dimensional Diffusion of a Phospholipid Monolayer
Published on: October 15, 2015
06:29Effect of Artificial Tear Formulations on the Metabolic Activity of Human Corneal Epithelial Cells after Exposure to Desiccation
Published on: May 2, 2020
Related Concept Videos
Fluorescence and Phosphorescence: Instrumentation
Total Internal Reflection Fluorescence Microscopy