Related Experiment Video
Updated: Aug 16, 2025

Shaping the Amplitude and Phase of Laser Beams by Using a Phase-only Spatial Light Modulator
Published on: January 28, 2019
Thermooptical PDMS-Single-Layer Graphene Axicon-like Device for Tunable Submicron Long Focus Beams
Giancarlo Margheri1, André Nascimento Barbosa2, Fernando Lazaro Freire2
1Institute for Complex Systems of National Council of Researches of Italy, Separate Location of Sesto Fiorentino, Via Madonna del Piano, Sesto, 50019 Florence, Italy.
Abstract:
Submicron long focusing range beams are gaining attention due to their potential applications, such as in optical manipulation, high-resolution lithography and microscopy. Here, we report on the theoretical and experimental characterization of an elastomeric polydimethylsiloxane/single layer graphene (PDMS/SLG) axicon-like tunable device, able to generate diffraction-resistant submicrometric spots in a pump and probe configuration. The working principle is based on the phase change of an input Gaussian beam induced in the elastomer via the thermo-optical effect, while the heating power is produced by the optical absorption of the SLG. The phase-modified beam is transformed by an objective into a long focus with submicron diameter. Our foci reach an experimental full width at half maximum (FWHM) spot diameter of 0.59 μm at the wavelength of 405 nm, with the FWHM length of the focal line greater than 90 μm. Moreover, the length of the focal line and the diameter of the focus can be easily tuned by varying the pump power. The proposed thermo-optical device can thus be useful for the simple and cheap improvement of the spatial resolution on long focus lines.