Related Experiment Video
Updated: Aug 16, 2025

09:03
A Silicon-tipped Fiber-optic Sensing Platform with High Resolution and Fast Response
Published on: January 7, 2019
7.2K
A High-Sensitivity Dual-Axis Accelerometer with Two FP Cavities Assembled on Single Optical Fiber
Bolun Zheng1,2, Hanjie Liu1, Zhen Pan1
1National Engineering Research Center of Fiber Optic Sensing Technology and Networks, Wuhan University of Technology, Wuhan 430070, China.
Sensors (Basel, Switzerland)
|December 23, 2022
Summary
A novel dual-axis fiber optic accelerometer uses a Fabry-Pérot (FP) cavity to measure acceleration along X and Y axes. This sensor offers high sensitivity and immunity to electromagnetic interference.
Area of Science:
- Optoelectronics
- Fiber Optics Sensing
- Inertial Measurement
Background:
- Traditional accelerometers face limitations like electromagnetic interference and bulky designs.
- Fiber optic sensors offer advantages such as immunity to EMI, small size, and remote sensing capabilities.
Purpose of the Study:
- To propose and demonstrate a novel dual-axis fiber optic accelerometer based on the Fabry-Pérot (FP) interference principle.
- To evaluate the performance characteristics, including sensitivity, cross-axis sensitivity, and angular error, of the developed sensor.
Main Methods:
- A dual-axis FP accelerometer was constructed using a single optical fiber, a beam-splitting prism, and a vibration-sensitive Beryllium-Copper (Be-Cu) spring with a proof mass.
- Two perpendicular FP cavities were formed by a semi-permeable film on the prism and a reflective sheet on the spring.
- Vibration signals caused changes in cavity lengths, which were detected via optical interference, bandpass filtering, and demodulation to obtain dual-axis acceleration measurements.
Main Results:
- The dual-axis fiber optic accelerometer exhibited a resonant frequency of approximately 280 Hz.
- Sensitivities of 3.93 μm/g (X-axis) and 4.19 μm/g (Y-axis) were achieved.
- Cross-axis sensitivity was measured to be below 5.1%, and the maximum error within a 180° angle range was less than 3.77%.
Conclusions:
- The proposed fiber optic dual-axis FP accelerometer demonstrates high sensitivity, excellent immunity to electromagnetic interference, and potential for miniaturization and mass production.