Related Experiment Video
Updated: Aug 16, 2025

Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
Validity of a Smartphone Application in Calculating Measures of Heart Rate Variability
Andreas T Himariotis1,2, Kyle F Coffey1,2, Sabrina E Noel1,3
1Health Assessment Laboratory, University of Massachusetts Lowell, Lowell, MA 01854, USA.
Abstract:
The purpose of the current study was to determine the concurrent validity of the Elite HRV smartphone application when calculating heart rate variability (HRV) metrics in reference to an independent software criterion. A total of 5 minutes of R−R interval and natural log of root mean square of the successive differences (lnRMSSD) resting HRV data were simultaneously collected using two Polar H10 heart rate monitors (HRMs) in both the seated and supine positions from 22 participants (14 males, 8 females). One H10 HRM was paired with a Polar V800 watch and one with the Elite HRV application. When no artifact correction was applied, significant, but small, differences in the lnRMSSD data were observed between the software in the seated position (p = 0.022), and trivial and nonstatistically significant differences were observed in the supine position (p = 0.087). However, significant differences (p > 0.05) in the lnRMSSD data were no longer identifiable in either the seated or the supine positions when applying Very Low, Low, or Automatic artifact-correction filters. Additionally, excellent agreements (ICC3,1 = 0.938 − 0.998) and very strong to near-perfect (r = 0.889 − 0.997) relationships were observed throughout all correction levels. The Elite HRV smartphone application is a valid tool for calculating resting lnRMSSD HRV metrics.
Related Concept Videos
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Assessment of blood pressure in brachial artery(two-step method)
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Special considerations while measuring pulse
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:

