Related Experiment Video
Updated: Aug 16, 2025

Assessing Urinary Tract Junction Obstruction Defects by Methylene Blue Dye Injection
Published on: October 12, 2017
[Intravenous infusion of methylene blue to visualize the ureter in laparoscopic colorectal surgery]
Abstract:
Objective: Intraoperative localization of the ureter can contribute to accurate dissection and minimize ureteral injury in colorectal surgery. We aim to summarize a single center's experience of fluorescence ureteral visualization using methylene blue (MB) and explore its visualization efficiency. Methods: This is a descriptive case-series-study. Clinical data of patients who had undergone laparoscopic colorectal surgery and fluorescence visualization of the ureter in the Gastrointestinal Surgery Department of Guangdong Provincial People's Hospital from March 2022 to May 2022 were retrospectively collected. Patients with incomplete surgery videos, renal insufficiency, or allergic reactions were excluded. MB was infused with 0.9% NaCl at 1.0 mg/kg in 100 mL of normal saline for 5 to 15 minutes during laparoscopic exploration. Imaging was performed using a device developed in-house by OptoMedic (Guangdong, China) that operates at 660nm to achieve excitation of MB. Clinical information, MB dosage, rate of successful fluorescence, time to fluorescence, operation time, blood loss, intraoperative blood oxygen levels, pathological staging, changes in renal function, and post-operative complications were retrospectively analyzed. Results: The study cohort comprised 27 patients (24 men and 3 women) with an average age of (60.25±16.95) years and an average body mass index of (21.72±3.42) kg/m2. The dosage of MB was 0.3-1.0 mg/kg and the infusion time was 5-15 minutes. Fluorescence signals were detected in all patients. The median time to signal detection was 20 (range, 10 to 40) minutes after MB infusion. The range of intraoperative blood oxygen fluctuation averaged 2.5% (range, 0 to 7.0%). The median change in creatine concentration was -1.3 (range, -17.2 to 29.2) µmol/L. No patients had complications associated with use of MB. Fluorescence visualization of the ureter was very valuable clinically in two patients (thick mesentery, stage T4). Conclusion: MB is a safe and effective means of visualizing the ureter by fluorescence during laparoscopic colorectal surgery, especially when the procedure is difficult. MB in a dosage of less than 1 mg/kg can slowly infused for more than 5 minutes during laparoscopic exploration. During the infusion, attention must be paid to blood oxygen fluctuations.
More Related Videos
07:20Intraoperative Detection of Subtle Endometriosis: A Novel Paradigm for Detection and Treatment of Pelvic Pain Associated with the Loss of Peritoneal Integrity
Published on: December 21, 2012
03:27The Role of Indocyanine Green Fluorescence in Complex Laparoscopic Cholecystectomy Navigation
Published on: January 31, 2025
Related Concept Videos
Imaging Studies V: Intravenous Urography and Retrograde Pyelography
Urologic Endoscopic Procedure: Cystoscopic Examination
Imaging Studies I: Kidney, Ureter, and Bladder Studies
Imaging Studies IV: Magnetic Resonance Imaging
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Imaging Studies VI: Voiding Cystourethrography and Cystography