Related Experiment Video
Updated: Aug 16, 2025

A Coupled Experiment-finite Element Modeling Methodology for Assessing High Strain Rate Mechanical Response of Soft Biomaterials
Published on: May 18, 2015
A new mathematical model derived from transient (creep) analysis to estimate the vaginal retention of semi-solid
David S Jones1, Tao Yu1, Shu Li1
1School of Pharmacy, The Queen's University of Belfast, Medical Biology Centre, 97 Lisburn Road, Belfast BT9 7BL, Northern Ireland, United Kingdom.
Abstract:
The performance of vaginal drug delivery systems is dependent on their retention. This study presents a novel mathematical method to estimate the vaginal retention of semi-solids. Using creep analysis, the elastic and residual compliances are determined from the discrete retardation spectrum and used to determine the retention times (RT), defined as the time required for the formulations to enter the terminal viscous zone of deformation and hence flow. RT of commercially available products (CAP) and selected prototype formulations were determined, the estimated RT of CAP broadly aligning with their prescribed clinical usage. Candidate formulations composed of hydroxyethylcellulose (HEC, 3%/5%w/w) and polyacrylic acid (PAA, 1%/3%w/w) were manufactured using, and further diluted with simulant vaginal fluid (SVF) or simulant seminal fluid (SSF) and their RT subsequently determined. Increasing polymer concentration and pH enhanced the estimated RT whereas dilution reduced RT. Notably, the formulation composed of 5%HEC/3% PAA (SSF) maintained its RT on dilution due to swelling of suspended PAA particles, thus representing a strategy to develop vaginal semi-solids that are resistant to dilution and hence removal. The mathematical model described is reproducible, straightforward to use and is recommended as a tool in formulation development to estimate the retention of vaginal semi-solids.
More Related Videos
18:57Models and Methods to Evaluate Transport of Drug Delivery Systems Across Cellular Barriers
Published on: October 17, 2013
06:18Intravascular Ultrasound Image-Based Finite Element Modeling Approach for Quantifying In Vivo Mechanical Properties of Human Coronary Artery
Published on: December 6, 2024
Related Concept Videos
One-Compartment Open Model for IV Bolus Administration: Estimation of Elimination Rate Constant, Half-Life and Volume of Distribution
Two-Compartment Open Model: IV Bolus Administration
The disparity between drug input and the sum of drug transfer rates between...
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant,...
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
One-Compartment Open Model for Extravascular Administration: First-Order Absorption Model
Two-Compartment Open Model: IV Infusion
The model illustrates the decrease in plasma drug concentration from the central compartment with a specific equation. It shows that under steady-state conditions, the drug's input rate...