Related Experiment Video
Updated: Aug 16, 2025

Assessment and Communication for People with Disorders of Consciousness
Published on: August 1, 2017
Reliability of the Heartbeat Tracking Task to Assess Interoception
Lucas Eduardo Rodrigues Santos1, Hassan Mohamed Elsangedy2, Catarina Fernanda Costa Xavier Monteiro de Souza3
1Grad Program in Neuropsychiatry and Behavioral Sciences, Federal University of Pernambuco, Recife, PE, Brazil.
Abstract:
Interoception refers to the competence in perceiving and interpreting internal sensations emerging from the body. The most common approach to assess interoception is through cardiac interoceptive tests like the heartbeat tracking task (HTT), which measures the accuracy on perceive and counting heartbeats during a period. However, the literature is scarce in providing adequate reliability evidence for this measure so that the interoception assessment may be threaten. In addition to HTT accuracy, it is possible to determine sensibility (self-reported confidence) and interoceptive awareness (correspondence between accuracy and sensibility). Thus, we measured the test-retest reliability of HTT and also investigated the behavior of HTT outcomes along the task. Therefore, 31 healthy adults (16 males) with 27.8 (9.4) years old performed two consecutive HTT interspersed by one day. Intraclass correlation coefficient (ICC), standard error of measurement (SEM) and minimal detectable difference (MD) analyzes showed 'Good' relative reliability for interoceptive accuracy (ICC = 0.880; SEM = 0.263; MD = 0.728; p < 0.001) and 'Moderate' for sensibility (ICC = 0.617; SEM = 0.648; MD = 1.797; p < 0.001) and awareness (ICC = 0.593; SEM = 0.227; MD = 0.628; p < 0.001). The absolute reliability shows low threshold values for observing true effects in HTT outcomes. The results also showed that reducing the number of HTT blocks did not impact the outcomes. The HTT showed to be reliable in determine the interoceptive competences in healthy adults.
More Related Videos
08:40Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
09:04Uncovering Beat Deafness: Detecting Rhythm Disorders with Synchronized Finger Tapping and Perceptual Timing Tasks
Published on: March 16, 2015
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Special considerations while measuring pulse