[Design and application of a new heat-and-moisture exchanger with anti-splash sputum suctioning function]
Zhiyuan Fan1, Liufang Xu1, Zhonghua Shao1
1Department of Emergency, Tongxiang First People's Hospital, Tongxiang 314500, Zhejiang, China.
Abstract:
In the emergency department, open endotracheal suctioning for mechanically ventilated patients with endotracheal intubation will lead to the spread of respiratory droplets and aerosols, polluting the surrounding environment and medical staff. The traditional heat-and-moisture exchanger has the effect of warming and humidifying, and can block pathogenic microorganisms, but it does not have the function of inserting a sputum suction tube. When the heat-and-moisture exchanger is pulled out for sputum suction, it is easy to cause sputum splash, which pollutes the surrounding environment and medical personnel. The addition of closed sputum suction devices will increase the economic burden on patients. Thus, the medical staff of emergency department of the First People's Hospital of Tongxiang City of Zhejiang Province designed a new type of heat-and-moisture exchanger with anti-splash sputum suctioning function and obtained the National Utility Model Patent of China (ZL 2021 2 0017615.0). The new heat-and-moisture exchanger is mainly composed of a receiving cavity, a connecting tube, a sputum suction tube intubation tube, a sealing valve, etc. The disposable sputum suction tube can be used to insert sputum suction, and at the same time, it can prevent the secretion from splashing to ensure sealing. The patent combines the humidification and pathogen blocking functions of the heat-and-moisture exchanger with the anti-splash sputum suctioning function, which is suitable for use in the emergency and critical care medicine departments and has clinically practical value.
Related Concept Videos
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Suctioning the Nasopharyngeal Airway
Equipment Required
Tracheostomy Suctioning II: Procedure
Sputum Studies II: Culture and Sensitivity
Sputum culture and sensitivity is a medical procedure used to diagnose bacterial infections in the respiratory tract and select the most appropriate antibiotics for treatment. This process involves analyzing sputum samples of thick and opaque secretions produced in the lungs and airways. These samples are collected from patients and then sent to the laboratory for analysis.
The test can identify various pathogens responsible for respiratory infections, including Streptococcus,...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...