Construction of a Wireless-Enabled Endoscopically Implantable Sensor for pH Monitoring with Zero-Bias Schottky Diode-based Receiver
Published on: August 27, 2021
Encapsulation of Gas Sensors to Operate in the Gastrointestinal Tract for Continuous Monitoring
Hen-Wei Huang1, David de Gruijl1, Philip Fritz1
1Dept. of Medicine., Harvard Medical School, Boston, United States.
Abstract:
Recent advances in ingestible sensors have enabled in situ detection of gastrointestinal (GI) biomarkers which shows great potential in shifting the paradigm of diagnosing GI and systemic diseases. However, the humid, acidic gastric environment is extremely harsh to electrically powered sensors, which limits their capacity for long term, continuous monitoring. Here, we propose an encapsulation approach for a gas sensor integrated into a nasogastric (NG) tube that overcomes chemical corrosion, electrical short, and mechanical collision in a gastric environment to enable continuous gaseous biomarkers monitoring. The coating effects on the sensitivity, signal latency, and repeatability are investigated. Our long-term continuous monitoring in vitro results show that the proposed coating method enables the gas sensors to function reliably and consistently in the simulated GI environment for more than 1 week. The encapsulation is composed of Polycaprolactone (PCL) to protect against mechanical scratching and Parylene C to prevent a sensor from chemical corrosion and electrical short. The average life-time of the sensor with 10 micrometers Parylene coating is about 3.6 days. Increasing the coating thickness to 20 micrometers results in 10.0 days. In terms of repeatability, 10 micrometers and 20 micrometers Parylene C coated sensors have a standard deviation of 1.30% and 2.10% for its within sensor response, and 5.19% and 3.06% between sensors respectively.
More Related Videos
08:18Design and Use of a Full Flow Sampling System FFS for the Quantification of Methane Emissions
Published on: June 12, 2016
09:29Fabrication and Implantation of Miniature Dual-element Strain Gages for Measuring In Vivo Gastrointestinal Contractions in Rodents.
Published on: September 18, 2014
Related Concept Videos
Endoscopic Procedures III: Video Capsule Endoscopy
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...