Zero Echo Time vs. T1-Weighted MRI for Assessment of Cortical and Medullary Bone Morphology Abnormalities Using CT as
Jun Xu1, Yawen Hu1, Ruizhi Zhou1
1Department of Radiology, The Affiliated Hospital of Qingdao University, Qingdao, Shandong, China.
Background:
Conventional MR pulse sequences result in poor signal from low T2 cortical bone because the minimum achievable echo time is limited. A sequence resulting in improved bone contrast is desirable.
Purpose:
To evaluate the image quality and diagnostic performance of grayscale inversion zero echo time imaging (GI-ZTE) and grayscale inversion T1-weighted imaging (GI-T1WI) compared with computed tomography (CT).
Study Type:
Prospective.
Subjects:
A total of 50 patients with musculoskeletal tumors or tumor-like diseases of the lower extremities having MRI and CT studies.
Field Strength/Sequence:
GI-T1WI and GI-ZTE sequences at 1.5 T.
Assessment:
Assessed cortical and medullary bone morphology abnormalities using CT as the reference standard. Three radiologists scored the images quality and recorded nine metrics to assess the diagnostic performance.
Statistical Tests:
Differences in image quality were calculated using the Wilcoxon signed-rank test. The intraclass correlation coefficient (ICC) was used to analyze the agreement of quantitative lesion parameters between CT and MR sequences, as well as the interobserver reliability. A P value <0.05 was considered statistically significant.
Results:
Image quality score was significantly higher for CT images than GI-TIWI images. Except for radiologist 3 [4(0) vs 4 (1)], there was no significant difference in scores between CT and GI-ZTE [radiologist 1: 4 (0) vs 4 (0), P = 0.133; radiologist 2: 4 (0) vs 4 (0), P = 0.085]. There was good-excellent agreement between both MR sequences and CT for size, lesion number, location, sclerotic rim, expanded shell, destruction pattern, and matrix mineralization for all radiologists (ICC: 0.636-1.000). The consistency of periosteal reaction and penetration of the cortex was fair to good (0.481-0.729) between GI-T1WI and CT and good to excellent between GI-ZTE and CT (0.682-0.852).
Data Conclusions:
GI-ZTE images had superior intermodality agreement with CT images and allowed visualization of more cortical bone detail than GI-T1WI images.
Evidence Level:
1.
Technical Efficacy:
Stage 2.
More Related Videos
08:04Proximal Cadaveric Femur Preparation for Fracture Strength Testing and Quantitative CT-based Finite Element Analysis
Published on: March 11, 2017
07:10A Sectioning, Coring, and Image Processing Guide for High-Throughput Cortical Bone Sample Procurement and Analysis for Synchrotron Micro-CT
Published on: June 12, 2020
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT