Measurement of the Hepatic Venous Pressure Gradient and Transjugular Liver Biopsy
Published on: June 18, 2020
The Identical External Reference Point Standardized to the Zero-Reference Level for Measuring Both Central and
Niraj Karmacharya1, Madhur Dev Bhattarai2, Amita Pradhan3
1Department of Medicine, Civil Service Hospital, Kathmandu, Nepal.
This study found that measuring central venous pressure (CVP) from the mid-thoracic plane (MTP) aligns well with measurements from the midaxillary line (MAL). Jugular venous pressure (JVP) measurements from MTP also show better agreement with CVP than traditional methods.
Area of Science:
- Cardiovascular Physiology
- Medical Measurement Techniques
- Clinical Hemodynamics
Background:
- Discrepancies exist between central venous pressure (CVP) and jugular venous pressure (JVP) measurements.
- The mid-thoracic plane (MTP) is the zero-reference level (ZRL) for venous pressure, while the midaxillary line (MAL) is a common reference in the supine position.
- Traditional JVP measurements use the sternal angle plus 5 cm, and CVP is measured from MAL in the supine position.
Purpose of the Study:
- To compare CVP measured from MTP (CVP-MTP) with CVP measured from MAL (CVP-MAL).
- To compare JVP measured from MTP (JVP-MTP) and sternal angle plus 5 cm (JVP-SA+5).
- To evaluate the agreement between CVP and JVP measurements using MTP as a common reference point.
Main Methods:
- 150 patients underwent blind measurements of JVP-MTP, JVP-SA+5, CVP-MTP, and CVP-MAL.
- Measurements were taken in appropriate reclining positions for JVP and supine for CVP.
- Pearson correlation and Bland-Altman plots were used for pressure comparisons.
Main Results:
- CVP-MTP and CVP-MAL showed similar means, strong positive linear relationships (r=0.908), and good agreement.
- JVP-MTP was significantly higher than JVP-SA+5 (p < 0.001).
- JVP-MTP demonstrated better correlation and agreement with both CVP measurements compared to JVP-SA+5.
Conclusions:
- JVP measurements correlate better with CVP when both are referenced from MTP.
- MAL can serve as a practical reference for CVP measurement in the supine position.
- Standardizing measurements from identical external reference points, like MTP, is crucial for accurate CVP and JVP comparison.
More Related Videos
Related Concept Videos
Measurement of Blood Pressure
Pre-Procedural Guidelines for Assessing Blood Pressure
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: