H-mode dithering phase studies on ST40
Yasmin Andrew1, James Bland2, Peter Buxton2
1Blackett Laboratory, Imperial College London, London SW7 2AZ, UK.
Abstract:
The dithering H-mode phase, characterized by oscillations, is generally observed at input power values close to the L-H transition power threshold and low plasma collisionalities (low electron density and/or high plasma temperature). Measurements to characterize the dithering phase are presented for the low aspect ratio, high magnetic field tokamak, ST40. The dithering phase oscillation frequency is observed between 400 and 800 Hz and demonstrates an inverse relationship with core plasma density. Dithering phase H-modes are documented across a nonlinear, low-density power threshold operational space, with signature low- and high-density branches. The minimum power threshold for dithering H-mode access is measured at a core, line average electron density of 4.7(±0.5) × 1019 m-3, close to a predicted value of 4.1(±0.4) × 1019 m-3 from multi-machine studies. ASTRA calculated values of power coupled to the ion species, at the dithering H-mode transition, exhibit a similar nonlinear dependence on density. This analysis points to the important contribution of the ion thermal channel to the L-H phase transition. The low-frequency plasma density and D-alpha dithers appear to be accompanied by sudden bursts of magnetohydrodynamic (MHD) activity. A simple model is tested to demonstrate a possible scenario of self-regulation among turbulence, zonal flows, pressure (density) gradient and MHD activities. This article is part of a discussion meeting issue 'H-mode transition and pedestal studies in fusion plasmas'.
Related Concept Videos
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...