Objective:
Home blood pressure monitoring (HBPM) is an increasingly important tool in managing hypertension (HTN); however, its efficacy depends on its accuracy. This study aimed to explore the differences between blood pressure (BP) measurements conducted by patients and medical professionals and the patient demographic factors correlating with inaccurate self-measured BP levels.
Methods:
One hundred hypertensive patients completed a questionnaire inquiring about their health status and HBPM procedures and were filmed while measuring their BP using their own devices. A researcher then measured the patients' BP using a calibrated sphygmomanometer to assess the accuracy of patient-performed readings. This cross-sectional study was conducted in five primary healthcare centers in Kraków, Poland.
Results:
The mean differences in systolic and diastolic BP readings by patients and researchers were 8.36 mmHg (SD = 10.90 mmHg) and 2.16 mmHg (SD = 9.12 mmHg), respectively. Inaccuracies in patient BP measurements were associated with a less than high school education level, patients' age, and a family history of HTN.
Conclusion:
Patient self-measured BP levels were higher than researcher values, likely due to a higher patient error rate. Healthcare providers must increase training regarding correct HBPM techniques offered to patients; such efforts should be directed at all hypertensive patients, emphasizing the most error-prone demographics.
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Pre-Procedural Guidelines for Assessing Blood Pressure
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement