Device-guided slow breathing with direct biofeedback of pulse wave velocity - acute effects on pulse arrival time and
Thomas Mengden1, Martin Bachler2, Walter Sehnert3
1Kerckhoff Clinic, ESH Excellence Centre, Bad Nauheim, Germany.
Background:
There isevidence that device-guided slow breathing using biofeedback acutely reduces blood pressure (BP) and pulse wave velocity [i.e. increased pulse arrival time (PAT)].
Objectives:
The objectives of the study presented here were to test whether the results of changes observed in PAT in earlier studies are reproducible over 1 week and how changes in pulse wave velocity/PAT translate into absolute self-measured BP changes.
Methods:
Patients with a systolic BP 130-160 mmHg or treated essential hypertension (21 females/23 males) were trained to perform unattended device-guided slow breathing exercises for 10 min daily over 5 days. Furthermore, they were skilled to perform self-measurement of BP before and after the breathing exercise using a validated upper-arm device.
Results:
Office BP at screening [median (1, 3. Q)] was 137 (132, 142)/83 (79, 87) mmHg. We observed a significant ( P < 0.05) increase in PAT of 5 ms (SD 12.5 ms) on average after 10 min of guided breathing and an additional 1 ms ( P < 0.05, SD 8 ms) during the following 5 min of spontaneous breathing compared to baseline. PAT before the exercise remained constant over 5 days paralleled by constant self-measured BP before the exercise. Device-guided breathing was associated with a significant reduction of self-measured SBP of 5 mmHg ( P < 0.01, SD 8 mmHg). Data furthermore demonstrated that these changes were highly reproducible over 1 week.
Conclusions:
Device-guided slow breathing and biofeedback lead to reproducible and favorable changes (increase) in PAT and SBP (decrease).
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...