Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Multimodal holotomography for volumetric monitoring of host-pathogen interactions.

Biomedical engineering online·2026
Same author

Wnt-dependent Frizzled clustering is required for Dishevelled phosphorylation but insufficient for β-catenin stabilization.

Science signaling·2026
Same author

PGAM5 cleavage and oligomerization equilibrates mitochondrial dynamics under stress by regulating DRP1 function.

Journal of cell science·2025
Same author

Conformation and Dynamics of Monomeric, Phase-Separated, and Cross-Linked Resilin Biomaterials.

Journal of the American Chemical Society·2025
Same author

Line-scan imaging for real-time phenotypic screening of C. elegans.

The Review of scientific instruments·2025
Same author

Septin5 deletion enhances β-cell exocytosis by releasing microtubule-tethered insulin granules onto plasma membrane.

Nature communications·2025
Same journal

Multifunctional reconfigurable terahertz metasurface based on vanadium dioxide phase transition: achieving broadband absorption and efficient polarization conversion.

Applied optics·2026
Same journal

High-Q-factor electromagnetically induced transparency utilizing quasi-bound states in the continuum in an all-dielectric terahertz metasurface.

Applied optics·2026
Same journal

Automated stitching interferometry for high-precision metrology of X-ray mirrors.

Applied optics·2026
Same journal

Experimental demonstration of an approach to designing a metal-dielectric DBR resonant cavity structure.

Applied optics·2026
Same journal

High-precision wavefront reconstruction from a single-shot interferogram using a physics-driven hybrid feature calibration network.

Applied optics·2026
Same journal

Ultra-high-Q Fano resonance based on coupled topological corner states in Kagome photonic crystals.

Applied optics·2026
See all related articles

Related Experiment Video

Updated: Aug 15, 2025

Compact Lens-less Digital Holographic Microscope for MEMS Inspection and Characterization
10:28

Compact Lens-less Digital Holographic Microscope for MEMS Inspection and Characterization

Published on: July 5, 2016

10.4K

Practical approach for optimizing off-axis telecentric digital holographic microscope design.

Lei Jin, Ziyang Yu, Aaron Au

    Applied Optics
    |January 6, 2023
    PubMed
    Summary
    This summary is machine-generated.

    Researchers simplified telecentric digital holographic microscopy (TDHM) alignment for better cell imaging. New methods optimize the +1-order position, improving resolution and image quality for biological samples.

    More Related Videos

    Construction of a High Resolution Microscope with Conventional and Holographic Optical Trapping Capabilities
    09:12

    Construction of a High Resolution Microscope with Conventional and Holographic Optical Trapping Capabilities

    Published on: April 22, 2013

    12.3K
    Author Spotlight: Advancing Knowledge in Far-From-Equilibrium Materials Through Light-Sheet Microscopy
    08:32

    Author Spotlight: Advancing Knowledge in Far-From-Equilibrium Materials Through Light-Sheet Microscopy

    Published on: January 26, 2024

    2.3K

    Related Experiment Videos

    Last Updated: Aug 15, 2025

    Compact Lens-less Digital Holographic Microscope for MEMS Inspection and Characterization
    10:28

    Compact Lens-less Digital Holographic Microscope for MEMS Inspection and Characterization

    Published on: July 5, 2016

    10.4K
    Construction of a High Resolution Microscope with Conventional and Holographic Optical Trapping Capabilities
    09:12

    Construction of a High Resolution Microscope with Conventional and Holographic Optical Trapping Capabilities

    Published on: April 22, 2013

    12.3K
    Author Spotlight: Advancing Knowledge in Far-From-Equilibrium Materials Through Light-Sheet Microscopy
    08:32

    Author Spotlight: Advancing Knowledge in Far-From-Equilibrium Materials Through Light-Sheet Microscopy

    Published on: January 26, 2024

    2.3K

    Area of Science:

    • Biomedical Imaging
    • Optical Microscopy
    • Cell Biology

    Background:

    • Digital holographic microscopy (DHM) is valuable for analyzing living cells and tissues.
    • Telecentric DHM (TDHM) reduces computational load via aberration corrections.
    • TDHM requires precise optical alignment for optimal resolution and image quality, posing a challenge.

    Purpose of the Study:

    • To develop simplified methodologies for TDHM design and alignment.
    • To determine the optimal +1-order position for improved performance.
    • To facilitate easier and more accurate TDHM system setup.

    Main Methods:

    • Derivation of methodologies from optical interference functions.
    • Determination of optimal +1-order position based on beam angles and interference plane rotation.
    • Experimental testing and verification on a TDHM system.

    Main Results:

    • Successfully simplified the TDHM design and alignment process.
    • Identified optimal parameters for the +1-order position.
    • Demonstrated improved image quality and resolution in experimental tests.

    Conclusions:

    • The proposed methodologies significantly simplify TDHM alignment.
    • Optimized alignment leads to enhanced resolution and image quality.
    • This work facilitates broader application of TDHM in biological imaging.