Related Experiment Video
Updated: Aug 15, 2025

Synergizing Antegrade Endoscopic with Bridging Vein Harvesting for Improvement of Great Saphenous Vein Graft Quality from the Lower Leg
Published on: November 19, 2019
Multiple Arterial Graft Use in Coronary Artery Bypass Surgery: Surgeon Perspective vs Practice
Ana K Velez1, Diane Alejo1, Sari D Holmes2
1Division of Cardiac Surgery, Department of Surgery, Johns Hopkins University School of Medicine, Baltimore, Maryland.
Background:
Despite supportive evidence and guidelines, the use of multiple arterial grafts (MAGs) in coronary artery bypass grafting remains low. We sought to determine surgeon perception of personal MAG use and compare this with actual MAG use.
Methods:
We conducted a statewide surgeon survey of MAG use, presence of a hospital MAG protocol, and barriers for MAG use, with a response rate of 78% (n = 25). Surgeon survey responses were compared with actual Society of Thoracic Surgeons patient data from January 1, 2017, to December 31, 2020 using χ2 or Fisher's exact tests.
Results:
Of 5299 patients who had first-time, nonemergent, isolated coronary artery bypass grafting (≥2 grafts) by responding surgeons, 16% received MAG (n = 825). MAG use in patients whose surgeons self-designated as "routine" MAG users was 21% vs 7% for "nonroutine" users. Surgeons with a hospital protocol for MAG use utilized MAG more often (18% vs 14%, P = .001). Surgeons who were unconvinced by the data on the benefits of MAGs used MAGs in 11% vs 22% in surgeons who were convinced. MAG use increased over time, particularly from before to after the survey (13.1% vs 30.5%, P < .001).
Conclusions:
Although MAG use increased over time, barriers to routine use remain. In surgeons who reported routine use, only 21% of their patients received MAGs. Hospital protocols, education, and increased awareness may reduce barriers to use and encourage evidence-based clinical practice.